SAFE HANDLING TIPS FOR LIQUID PROPANE GAS CYLINDERS
• LiquidPropane(LP)gasisapetroleumproductasarepetrolandnaturalgas.LPgas
is a gas at normal temperatures and pressures. Under moderate pressure, inside a
cylinder, LP gas is a liquid. As the pressure is released, the liquid readily vapourises
and becomes gas.
• LPgashasanodoursimilartonaturalgas.Youshouldbeawareofthisodour.
• LPgasisheavierthanair.LeakingLPgasmaycollectinlowareasandprevent
dispersion.
• TheLPcylindermustbeinstalled,transportedandstoredinanuprightposition.LP
cylinders should not be dropped or handled roughly.
• NeverstoreortransporttheLPcylinderwheretemperaturescanreach51°C(toohot
to hold by hand - for example: do not leave the LP cylinder in a car on a hot day).
• Treat“empty”LPcylinderswiththesamecareaswhenfull.EvenwhentheLPtank
is empty of liquid there still may be gas pressure in the cylinder. Always close the
cylinder valve before disconnecting.
• DonotuseadamagedLPcylinder.DentedorrustyLPcylindersorLPcylinders
with a damaged valve may be hazardous and should be replaced with a new one
immediately.
• ThejointwherethehoseconnectstotheLPcylindermustbeleak-testedeachtime
the LP cylinder is reconnected. For example, test each time the LP cylinder is refilled.
• Besuretheregulatorismountedwiththesmallventholepointeddownwardsothatit
will not collect water. This vent should be free of dirt, grease, insects etc.
◆
GAS INSTRUcTIONS
REPLAcEmENT HOSE, REGULATOR AND VALVE ASSEmbLY
m IMPORTANT NOTICE: We recommend that you replace the
gas hose assembly on your Weber gas barbecue every
5 years. Some countries may have requirements that the
gas hose be replaced within less than 5 years, in which
case that country’s requirement would take precedence.
For replacement hose, regulator, and valve assemblies,
contact the Customer Service Representative in your area
using the contact information on our web site.
Log on to www.weber.com
®
.
cOUNTRY GAS TYPE & PRESSURE
Bulgaria, Cyprus, Czech Republic, Denmark,
Estonia, Finland, Hungary, Iceland, Latvia,
Lithuania, Malta, Netherlands, Norway, Romania,
Slovak Republics, Slovenia, Spain, Sweden, Turkey
I
3
B/P - 30 mbar
Belgium, France, Greece, Ireland, Italy,
Luxembourg, Portugal, Switzerland,
United Kingdom
I
3+
- 28-30 / 37 mbar
Poland I
3
B/P - 37 mbar
Austria, Germany I
3
B/P - 50 mbar
cONSUmPTION DATA
Propane kW Butane kW
Genesis
®
310 11,14 12,7
Genesis
®
330 17, 58 20,1
Propane g/h Butane g/h
Genesis
®
310 796 924
Genesis
®