Rotary indexing ring TR
Maintenance
10. Mount the cover [9] by means of the screws.
11. Reconnect the motor and the holding brake
(see operating instructions of the motor
manufacturer).
12. Remove all tools and equipment.
13. Perform a test run.
15.4 Inspecting the toothed belt
DANGER
ELECTRIC SHOCK CAUSED BY LIVE PARTS
Failure to follow these instructions will result in death or serious injury.
■
Disconnect the mains supply voltage before performing the work and ensure that
it cannot be switched on.
■
Verify that no hazards can be caused by electrically conductive objects.
■
Verify that all cables for the power supply are disconnected from power.
WARNING
MISSING PROTECTIVE EQUIPMENT
Failure to follow these instructions can result in death, serious injury, and
equipment damage.
■
Immediately reinstall protective equipment that you may have removed to
perform maintenance work after having completed the maintenance work and
verify the effectiveness of the protective equipment.
WARNING
MOVING PARTS
Failure to follow these instructions can result in death, serious injury, and
equipment damage.
■
Verify that the zone of operation of the moving parts of the product/machine is
safeguarded.
Mounting instructions_062019_4.0_en
57 / 79