Errors Indication Possible cause Troubleshooting
the motor stops the door is warped
the contact pressu-
re is too high
the lock is too tight
adjust the door
check the ope-
ration via profile
cylinderhandle
the motor fun-
ctions but the
door cannot be
opened
the main bolt is
unlocked via profile
cylinder
Operating forces
too high faulty
installation
draw the main bolt
back again via the
profile cylinder
check installation
(keep alignment
air gap etc)
Power failure
whenduring
a) the door is
locked
the door can be
operated mecha-
nically (profile
cylinderhandle)
b) the door is
open lock is
unlocked
the door is pos-
sibly not held
by the latch
the motor is not in
starting position
close the door by
pre-locking the
main bolt if neces-
sary
c) the un-
locking
procedure
when the door
is locked again
possibly the
hook main bolt
do not lock
completely
the motor is not in
starting position
door can be ope-
rated mechanically
(profile cylinder
handle) if motor
has returned to
starting position
completely func-
tions
EAV does not
operate with
remote but LED
is illuminating
door doesn‘t
open
remote battery
dead
replace battery in
remote control
out of range to the
remote control
operate remote
control within
 mtrs
(unostructed)
remote control not
autthorized
check remote
control program-
med

Table of Contents