Loading...
Adjustment and maintenance
10.2011 ES 7100 PLUS 75
Espresso brewer unit maintenance
Every 10,000 selections or every 6 months
some maintenance of the coffee unit must be
carried out.
Turn off the main switch.
Remove the dispense head, the bracket
for dispense head and finally the brewer
(see deep cleaning, page 39 and
page 41).
Removing the upper filter
Loosen and remove nut (a, fig. 63), using
e.g. a spanner.
Press the shaft of the upper piston out of
the cross-piece (b, fig. 63) from above,
and remove piston (c, fig. 63).
Disassemble the filter (d) and the piston
seal (e, fig. 64) by removing screw
(f, fig. 64).
a
b
c
d
e
f
63 64