Occasional routines
50 ES 7100 PLUS 10.2011
Cleaning the brewer with cleaning
tablet
For cleaning, use products specifi-
cally intended for coffee machines,
only. Strictly observe the produc-
er’s instructions for storage, han-
dling and dosage.
Turn the door key clockwise in keyhole
and open the door.
Turn the machine off with main switch
(fig. 59) before disassembling parts in
connection with the brewer parts.
Preparing the brewer cleaning with cleaning tablet
Remove hoses with spouts from dispense
head: turn each spout until its locking tab
can be released through the notch of the
hole in dispense head and lift off the spout
Remove the dispense head by pulling it
forwards.
Lift off the ingredient waste shelf.
Remove the bracket for dispense head by
loosening the securing bolt.
Remove the inlet hose and the piston
hose: Press the green locking ring of each
quick coupling at top of the brewer.
Loosen the securing bolt retaining the
brewer to its bracket.
Remove the brewer
Flush the brewer under a water tap to
remove all coffee remnants from upper
and lower filter.
Wipe dry the brewer with a clean, dry
cloth.
Reinsert the brewer and the other parts in
reverse order.