EasyManua.ls Logo

WMF 900 - Page 70

WMF 900
93 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Care
63
Foamer, variant A:
> Twist out the air intake pipe (9d) from the milk foamer.
> Unscrew the black cap (9e) from the air intake pipe.
Foamer, variant B:
> Detach the attachment (9d) and the sealing cap (9e) one by one from the milk foamer
> Fill the dispensing chamber (a) of the WMF milk system cleaner, by holding the closed bottle upright
and pressing it. The bottle must be de nitely held closed.
Hazard!
Hazard of eye injury!
In case of eye contract, the WMF milk system cleaner can lead to serious eye injuries.
> Ensure that the WMF Milk system cleaner never comes in contact with the eyes of humans or animals.
> Open the lid of WMF Milk system cleaner.
> Mix one measuring cap of WMF milk system cleaner and 200 ml water in a container.
> Place all parts of the milk system in the cleaning solution for minimum 5 hours or overnight.
Foamer, variant B:
> Foamer, variant B: Check the notches on the attachment (9d) specifi cally for visible contamination
and clean these, if necessary.
> Finally, rinse all the parts thoroughly under running water.
> Clean the beverage spouts with the brushes provided (b).
> Dry the parts with a cloth and allow it to dry completely before the assembly.
> Reassemble the milk foamer by connecting the upper and lower parts together:
Using milk system
cleaner
a
b
Reassembling the
parts