Electric Cooktop -2
Troubleshooting Guide
5-8
Error
Priority
Displayed
Error
Message
Error Condition Explanation Action that should be taken
3 E74 Open Circuit
associated with
FastOn E4 -Check
element or wiring
Self Test Result - The power
module detected a connector,
wiring, or element open
associated with terminal E4.
1. Check element for correct
connections and element damage
2. Check wiring at power module for
correct connection.
3 E75 Open Circuit
associated with
FastOn E5 -Check
element or wiring
Self Test Result - The power
module detected a connector,
wiring, or element open
associated with terminal E5.
1. Check element for correct
connections and element damage
2. Check wiring at power module for
correct connection.
3 E76 Open Circuit
associated with
FastOn E6 -Check
element or wiring
Self Test Result - The power
module detected a connector,
wiring, or element open
associated with terminal E6.
1. Check element for correct
connections and element damage
2. Check wiring at power module for
correct connection.
3 E77 Open Circuit
associated with
FastOn E7 -Check
element or wiring
Self Test Result - The power
module detected a connector,
wiring, or element open
associated with terminal E7.
1. Check element for correct
connections and element damage
2. Check wiring at power module for
correct connection.
3 E78 Open Circuit
associated with
FastOn E8 -Check
element or wiring
Self Test Result - The power
module detected a connector,
wiring, or element open
associated with terminal E8.
1. Check element for correct
connections and element damage
2. Check wiring at power module for
correct connection.
3 E79 Open Circuit
associated with
FastOn E9 -Check
element or wiring
Self Test Result - The power
module detected a connector,
wiring, or element open
associated with terminal E9.
1. Check element for correct
connections and element damage
2. Check wiring at power module for
correct connection.
3 E80 Open Circuit
associated with
FastOn E10 -Check
element or wiring
Self Test Result - The power
module detected a connector,
wiring, or element open
associated with terminal E10.
1. Check element for correct
connections and element damage
2. Check wiring at power module for
correct connection.
3 E81 Open Circuit
associated with
FastOn E11 -Check
element or wiring
Self Test Result - The power
module detected a connector,
wiring, or element open
associated with terminal E11.
1. Check element for correct
connections and element damage
2. Check wiring at power module for
correct connection.
3 E82 Open Circuit
associated with
FastOn E12 -Check
element or wiring
Self Test Result - The power
module detected a connector,
wiring, or element open
associated with terminal E12.
1. Check element for correct
connections and element damage
2. Check wiring at power module for
correct connection.
3 E83 Open Circuit
associated with
FastOn E13 -Check
element or wiring
Self Test Result - The power
module detected a connector,
wiring, or element open
associated with terminal E13.
1. Check element for correct
connections and element damage
2. Check wiring at power module for
correct connection.
3 E84 Open Circuit
associated with
FastOn E14 -Check
element or wiring
Self Test Result - The power
module detected a connector,
wiring, or element open
associated with terminal E14.
1. Check element for correct
connections and element damage
2. Check wiring at power module for
correct connection.