Boiler service functions
3 Boiler service functions
3.1 Summary
Text display message Display
Range adjustable
from - to
Reset
Value
0.0 Last fault 00 - FF Clear only 0
0.1 Flow temp. sensor 0 - 99 °C - -
0.2 Hot water temp. sensor 0 - 99 °C - -
0.3 Stor. tank temp. sensor1 0 - 99 °C - -
0.4 Stor. tank temp. sensor2 0 - 99 °C - -
1.2 Code plug 8714411 XXX 0 - 255 - -
1.5 Required flow temp. 0 - 99 °C - -
1.9 Module detection no module detected
bus module
--
2.0 Operating mode - normal
Min
Max
normal
2.2 Pump switch mode - 1 - 3 2
2.3 Stor. tank charge output - 0 - 100% 100 %
2.4 Anti-cycle mode - 0 - 15 min 3 min
2.5 Max. flow temperature - 35 - 88 °C 88 °C
2.6 Switch.diff.flow temperature - 0 - 30 °C 0 °C
2.7 Autom. anti-cycle mode - on
off
on
2.9 Actual output 0 - 100 % - -
3.0 Fan speed 0 - 255 U/s - -
3.3 Ionisations current no
low
middle
high
--
3.4 Pump mode - 0 - 3 0
1)
3.5 Pump blocking time - 0 - 240 s
in 15-s increments
0 s
3.6 Software version BF 11.XX - -
Table 1