Installation regulations
11
2 Installation regulations
Gas Safety (Installation & Use) Regulations 1998: All
gas appliances must be installed by a competent per-
son. Failure to install correctly could lead to prosecu-
tion.
The manufacturers notes must not be taken, in any way,
as overriding statutory obligations.
The appliance must be installed in accordance with the
current IEE Wiring Regulations, local Building Regula-
tions, Building Standards (Scotland) (Consolidation),
bye-laws of the local Water Company, Health and
Safety Document 635 (Electricity at Work Regulations
1989) and any other local requirements.
Product Liability regulations indicate that, in certain cir-
cumstances, the installer can be held responsible, not
only for mistakes on his part but also for damage result-
ing from the use of faulty materials. We advise the
installer to avoid any risk by using only quality approved
branded fittings.
The relevant British Standards should be followed i.e.
BS 6798: Specification for the installation of gas
fired hot water boilers of rated input not exceeding
60kW
BS 5449: Central Heating for Domestic Premises
BS 5546: Installation of gas hot water supplies for
domestic purposes
BS 5440:1: Flues and ventilation for gas appliances
of rated input not exceeding 70 kW (net): Flues
BS 5440:2: Flues and ventilation for gas appliances
of rated input not exceeding 70 kW (net): Air
Supply
BS 6891: Installation of low pressure gas pipework
installations up to 28mm (R1).
BS 7074:1: Code of practice for domestic heating
and hot water supply
BS 7671: Requirements for Electrical Installation.
These instructions must be followed.
3 Installation
3.1 Important remarks
B Appliance should only be installed in sealed central
heating and hot water systems.
B To avoid gas formation in the system, galvanised
radiators or pipes must not be used.
B If a room thermostat is used: do not fit a thermostatic
radiator valve on the radiator in the primary room.
B This appliance uses an automatically variable pump.
An auto-bypass must not be fitted.
B Add a suitable anti-freeze fluid to the water in the
central heating system.
Suitable products are available from Betz-Dearborn
Tel.: 0151 4209563 and Fernox Tel.: 01799
550811.
B In our experience, the addition of sealing agents to
the water in the central heating system can cause
problems (deposits in the heat exchanger). For that
reason we advise against their use.
B Always turn off the gas cock before car-
rying out any work on components
which carry gas.
i
Fixing of the appliance, gas and flue con-
nections, commissioning of the system
and electrical connections may only be
carried out by competent persons author-
ised by CORGI.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GREENSTAR HE combi Series and is the answer not in the manual?

Worcester GREENSTAR HE combi Series Specifications

General IconGeneral
BrandWorcester
ModelGREENSTAR HE combi Series
CategoryBoiler
LanguageEnglish

Related product manuals