7 181 465 347 (01.07)8
Boiler service functions
6.8 Cycle time (hot water) - 0 - 60 min 0 min
6.9 Duration (hot water) - 0 - 30 min 1 min
7.0 Pump map (heating) - 0 Pump step adjustable
1 Const. pressure high
2 Const. pressure
middle
3 Const. pressure low
4 Prop.pressure high
5 Prop.pressure low
4 Prop.
pres-
sure
high
7.1 Map pump step (heat.). - 2 - 7 7
7.2 Antiblock. map pump. - off
on
on
7.3 Air purge mode - off
on autom. deaktivat.
permanent on
on
autom.
deaktiv
at./ off
7.4 Actual map pump step 1 - 8 - -
7.5 Map pump load index 0 ... 255 - -
7.6 Map pump type 0 .. 99 - -
7.7 Output reduction - off
only in heating mode
only in hot water mode
in heat./hot water mode.
only in
heating
mode
8.5 Siphonfillprogram - on, boiler min.output,
on, adjust. min output,
off
on,
boiler
min.
output
9.2 Hot water on demand - off
on
on
9.3 GFA-Asic-error 00h - FFh - -
1) The reset value depends on the code plug.
Text display message Display
Range adjustable
from - to
Reset
Value
Table 1