B Loosen any deposits in the heat exchanger from top
to bottom using the cleaning blade. Refer to fig. 52.
Fig. 52
B Clean the heat exchanger from top to bottom using
the brush. Refer to fig. 53.
Fig. 53
B Remove the fan and the burner (see section headed
“Burner”) and flush the heat exchanger from the top.
B Clean out the condensate collector and trap connec-
tion (with other end of brush).
Fig. 54
B Refit the clean-out cover using a new seal and
tighten screws to torque of approx. 5 Nm.
Burner
B Check that the gas cock is turned off and the master
switch is in the OFF position.
B Remove the clips (1) and unscrew the two bolts (2).
Refer to fig. 55.
B Unscrew and remove the two hexagon screws secur-
ing the fan (3).
B Slacken fully the rear securing bolt (4).
B Remove the burner coverplate.
Fig. 55
B Remove burner and clean components. Do not use a
wire brush. Refer to fig. 56.
Fig. 56
B Re-assemble burner in reverse order using a new
seal.
B Adjust gas/air ratio. Refer to section 7.2.
6 720 610 332-73.1R
6 720 610 332-74.1R
6 720 610 332-75.2R
1.
2.
4.
7 181 465 330-04.1R
3.
7 181 465 330-08.1R

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GREENSTAR HE combi Series and is the answer not in the manual?

Worcester GREENSTAR HE combi Series Specifications

General IconGeneral
BrandWorcester
ModelGREENSTAR HE combi Series
CategoryBoiler
LanguageEnglish

Related product manuals