System Specifications
86 Freedom XC Owner's Guide
System Specifications
Freedom XC 1000 Freedom XC 2000
Transfer relay rating (A
a
) 30A (24A continuous)
Transfer time (milliseconds
b
)
Shore to inverter:
Inverter to shore:
<20milliseconds
<20milliseconds with a 20-second delay
Transfer voltage (V)
Shore to inverter:
Inverter to shore:
<85V and >140V
<135V and >90V
Cooling
Fan, activated by any of the following:
High internal temperature
High AC output power
Table 19System specifications
a
Circuit breakers shall not carry more than 80% of their UL current rating continuously.
b
To change the AC Transfer time (mode), see Adjusting Settings in Configuration Mode on page 51.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Freedom XC 2000 and is the answer not in the manual?

Xantrex Freedom XC 2000 Specifications

General IconGeneral
Continuous Power2000W
Surge Power4000W
Input Voltage12V DC
Output Voltage120V AC
Output Frequency60 Hz
WaveformPure Sine Wave
Efficiency90%
Operating Temperature-4°F to 140°F (-20°C to 60°C)
Transfer Time20ms