Operating in Battery Mode
975-0784-01-01 59
Turning the Audible Alarm ON or OFF
The Freedom XC’s audible alarm can be muted. See Adjusting
Settings in Configuration Mode on page 51.
Any warnings such as error or fault conditions or imminent
shutdown are both displayed on the LCD screen and sounded on
the alarm speakers. See To manually reset the alarm: on page 59.
Audible alarm for warning: The unit beeps once when a warning
condition is detected.
Audible alarm for error: The unit beeps once every 5 s for 1 min.
To mute the alarm:
n Press any one of the three function buttons.
The alarm is automatically muted after 1 min. But the error code
continues to be displayed until the error is cleared.
To manually reset the alarm:
1. Press the Power button to turn it Off (from a down position to
up) and press again to turn it On to reset an active alarm and
clear the error.
2. If the Inverter Ignition Control is set to auto-on, toggle the
ignition signal to clear the alarm and error.
3. Toggle the AC input power to force the transition between
grid mode and battery mode. This action clears the alarm
and error.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Freedom XC 2000 and is the answer not in the manual?

Xantrex Freedom XC 2000 Specifications

General IconGeneral
Continuous Power2000W
Surge Power4000W
Input Voltage12V DC
Output Voltage120V AC
Output Frequency60 Hz
WaveformPure Sine Wave
Efficiency90%
Operating Temperature-4°F to 140°F (-20°C to 60°C)
Transfer Time20ms