Operating in Grid Mode
68 Freedom XC Owner's Guide
Overload Conditions
There are two kinds of overload conditions–an overload warning
and an overload shutdown.
Overload
Warning
When the Freedom XCs AC load is approximately 100W
below the overload shutdown limit of rated watts, the
audible alarm beeps once and the LCD screen shows a
warning code E06.
Overload
Shutdown
When the Freedom XCs AC load increases to near
~1100W (Freedom XC 1000) and ~2100W (Freedom
XC 2000), the audible alarm beeps every five seconds
for one minute and the LCD screen shows a error code
E03. The Status LED turns solid RED.
High Surge Loads
Some induction motors used in freezers, pumps, and other motor-
operated equipment require high surge currents to start. The
Freedom XC may not be able to start some of these motors even
though their rated steady state current draw is within the
inverter/charger’s limits. The unit will shut down and indicate an
overload shutdown.
Over-temperature Conditions
During inverter operation, when the Freedom XC’s internal
temperature starts to approach its preset shutdown limit, the
display will show error code E07. If the over-temperature condition
persists, the display will show error code E04. The Status LED
turns solid RED and the inverter/charger will shut down to prevent
damage to the inverter/charger and protect the battery from being
over-discharged.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Freedom XC 2000 and is the answer not in the manual?

Xantrex Freedom XC 2000 Specifications

General IconGeneral
Continuous Power2000W
Surge Power4000W
Input Voltage12V DC
Output Voltage120V AC
Output Frequency60 Hz
WaveformPure Sine Wave
Efficiency90%
Operating Temperature-4°F to 140°F (-20°C to 60°C)
Transfer Time20ms