Operating in Grid Mode
975-0784-01-01 67
Operating
Condition
Battery
Voltage
Comment
Low
Voltage
Shutdown
<LBCO
The buzzer sounds a single one-
second low battery alarm beep
and the LCD screen shows error
code E01. After LBCO Shutdown
delay timer runs out, the unit shuts
down inverter output. The buzzer
stops beeping and the LCD screen
shows error code E01.
Instant Low
Voltage
Shutdown
<9.0 volts
After two seconds below the limit,
the unit shuts down inverter output
completely. LCD screen turns off
completely.
Operating
Condition
Battery
Voltage
Comment
High
Voltage
Shutdown
18.0 volts
The display shows error code E02
alternating with the battery
voltage. The red status LED turns
on.
NOTE: Although the Freedom XC
incorporates over-voltage
protection, it can still be damaged
if input voltage exceeds 18.0(or
32.0) volts.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Freedom XC 2000 and is the answer not in the manual?

Xantrex Freedom XC 2000 Specifications

General IconGeneral
Continuous Power2000W
Surge Power4000W
Input Voltage12V DC
Output Voltage120V AC
Output Frequency60 Hz
WaveformPure Sine Wave
Efficiency90%
Operating Temperature-4°F to 140°F (-20°C to 60°C)
Transfer Time20ms

Related product manuals