Installation Xerox
®
Versant™ 2100 Press
Customer Expectation and Installation Guide Xerox Confidential 36
Optional
finishing
device
Current /
run power
Voltage
(VAC)
Power
cord
length
Receptacle
NEMA part
number
Interface
Module
1.5
amps/85
watts
100-240 8.2
feet/2.5
meters
5-15R
GBC
Advanced-
Punch Pro
1.2
amps/340
watts
100-240 8.2
feet/2.5
meters
5-15R
High
Capacity
Stacker (HCS)
0.8
amps/70
watts
100-240 8.2
feet/2.5
meters
5-15R
Standard
Finisher
2 amps/70
watts
100-240 8.2
feet/2.5
meters
5-15R
Booklet
Maker
Finisher
2 amps/70
watts
100-240 8.2
feet/2.5
meters
5-15R
SquareFold
Trimmer
Module
0.4
amps/96
watts
100-240 8.2
feet/2.5
meters
5-15R
2-Knife
Trimmer
Module
4 amps /
250 watts
100-230 14.8
feet/4.5
meters
5-15R
NOTE: The Standard Finisher Plus requires two NEMA receptacles (NEMA 5-
15R or 5-20R).
Electrical Requirements for the Print Servers
FreeFlow Print Server
Print Server
Item
Current /
run
power
Voltage
(VAC), North
America
(NA)
Power
cord
length
Receptacle
NEMA part
Monitor 1.5 amp
25 watts
100-240v
50/60 Hz
+/-3Hz
7.5
feet/2.3
meters
5-15R
Controller
(hard drive)
3.5
amps
400
Watts
100-240 V
50/60 Hz
7.5
feet/2.3
meters
5-15R
EX 2100 Print Server
Print Server
Item
Current /
run
power
Voltage
(VAC),
North
America
(NA)
Power
cord
length
Receptacle
NEMA part
number
Monitor 1.2 amp
100-240v
47-63 Hz
7.5
feet/2.3
meters
5-15R
Controller
(hard drive)
5 amps
100-240 V
47/63 Hz
7.5
feet/2.3
meters
5-15R
EX 2100 Print Server
Print Server
Item
Current / run
power
Voltage
(VAC),
North
America
(NA)
Power
cord
length
Receptacle
NEMA part
number
Monitor
1.2 amp
100-240v
47-63 Hz
7.5
feet/2.3
meters
5-15R
Controller
(hard
drive)
0-8
amps
200 watts, 2
amps (typical)
400 watts, 3.5
amps (max)
100-240 V
47/63 Hz
7.5
feet/2.3
meters
5-15R
Determining the Amp/Circuit Requirements
Use the following formula to determine/calculate the amperage/circuit
requirements for all devices associated with the press (left and right
modules only); this includes the Print Server, Avanced HCF (single and
chanined), and optional finishing devices.
NOTE: This formula does not calculate the press (left and right modules)
since it is on its own dedicated circuit.
1. Determine the amps required for each device.
2. Calculate the total amp sum of all the devices.
3. The sum total is:
12 or below; therefore, a 15 amp circuit may be used with NEMA 5-
15R. However, a 20 amp circuit is recommended using NEMA 5-
20R receptacles.
12.1 - 16; a 20 amp circuit is required (NEMA 5-20R receptacles).
4. Calculate the total number of devices associated with the press,
including the Print Server, feeding, and all optional finishing devices.
This calculation is number of receptacles required. Refer to the
following two examples.
Example 1
Device
Amps
FreeFlow Print Server Monitor: 1.5 amps
Controller (hard drive): 3.5 amps
5
OHCF
3
Inter
f
ace Module
1.5
HCS
0.8
Total amount of
amps required
Total number of required circuits
10.3 amps
One 15 amp circuit with 5 receptacles (NEMA 5-
15R): 1 for each device.
You may consider using two 15 amp circuits: one
for the Print Server and the other for the
remaining devices; or one 20 amp circuit (NEMA
5-20R).
Example 2
Device
Amps
FreeFlow Print Server Monitor: 1.5 amps
Controller (hard drive): 3.5 amps
5
OHCF
3
Inter
f
ace Module
1.5
GBC AdvancedPunch
Pro
1.2
HCS
0.8
2
nd
HCS
0.8
Booklet Maker Finisher
2
SquareFold Trimmer Module 0.4
Optional feeding /
finishing device
Current
(amps)
Voltage
(VAC)
Power
cord
length
Receptacle
NEMA part
number
Standard
Finisher
Plus
Finisher
Module
1 amps 100-
240
8.2
feet/2.5
meters
5-15R
Finisher
Transport
5 amps 100-
240
8.2
feet/2.5
meters
5-15R