FusionServer 2288H V6 Server
Technical White Paper
5 Hardware Description
2022-06-25
102
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Steady on
Blinking at 1 Hz
The drive is being located.
Blinking at 1 Hz
Blinking at 1 Hz
Data on the secondary drive is being rebuilt.
Off
Steady on
A drive in a RAID array is removed.
Steady on
Steady on
The drive is faulty.
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The NVMe drive is not detected.
Steady on
Off
The NVMe drive is detected and operating
properly.
Blinking at 2 Hz
Off
Data is being read from or written to the
NVMe drive.
Off
Blinking at 2 Hz
The NVMe drive is being located.
Off
Blinking at 8 Hz
The data on the secondary NVMe drive is
being rebuilt.
Steady on/Off
Steady on
The NVMe drive is faulty.