3
E-123
V phase current
sampling zero
calibration
value error
Current sensor damaged
or external interference
too large
Check the ground wiring
or contact us
13
0
E-130
Encoder U
phase open
circuit
AB phase or UVW
open circuit when
self-checking
1. check encoder cable
wiring, use multi-meter to
measure the connection
2. change motor
1
E-131
Encoder V
phase open
circuit
AB phase or UVW
open circuit when
self-checking
1. check encoder cable
wiring, use multi-meter to
measure the connection
2. change motor
2
E-132
Encoder W
phase open
circuit
AB phase or UVW
open circuit when
self-checking
1. check encoder cable
wiring, use multi-meter to
measure the connection
2. change motor
14
0
E-140
Encoder A
phase open
circuit
A phase open circuit
when self-checking
Cut off the drive power
supply, check the
connection
1
E-141
Encoder B
phase open
circuit
B phase open circuit
when self-checking
Cut off the drive power
supply, check the
connection
2
E-142
Encoder Z
phase open
circuit
Z phase open circuit
when self-checking
Cut off the drive power
supply, check the
connection
15
0
E-150
Motor lack of
U phase
UVW phase open
circuit when
self-checking
Check power cable U/V/W
connection
0
E-151
Motor lack of
V phase
UVW phase open
circuit when
Check power cable U/V/W
connection

Table of Contents