Loading...
11
comparison value of
user-defined output 1 trigger
condition and setting
Related to
the trigger
condition
0
-9999~
9999
All
12
0: P5-10≥P5-11, output SOx
1: P5-10<P5-11, output SOx
2: P5-10 absolute value≥ P5-11,
output SOx
3: P5-10 absolute value <P5-11,
output SOx
-
0
0~3
All
13
User-defined output 1 hysteresis
loop
Related to
the trigger
condition
0
0~655
35
All
14
User-defined output 2 trigger
condition
-
0
0~FFF
F
All
15
comparison value of
user-defined output 2 trigger
condition and setting
Related to
the trigger
condition
0
-9999~
9999
All
16
0: P5-14≥P5-15, output SOx
1: P5-14≤ P5-15, SOx output
2: P5-14 absolute value ≥P5-15,
output SOx
3: P5-14 absolute value <P5-15,
output SOx
-
0
0~3
All
17
User-defined output 2 hysteresis
loop
Related to
the trigger
condition
0
0~655
35
All
18
IO filter time
ms
0
0~100
00
All
19
Z phase signal pulse width
ms
2
2~20
All