101
motor output torque
larger than P3-28,
P3-29, it will alarm
torque setting is
suitable
2. check external
mechanical
structure and
installation
6
E-166
Motor
temperature too
high
11KW and 15KW large
power motor encoder
cover is installed
thermistor, will alarm
when the temperature is
higher than 85°
1. check if the
machine has
blocked.
2. if the motor is
running over
speed at high
torque
17
0
E-170
Motor
undervoltage
when running
Bus voltage too low
when running
1. check the
power grid
voltage
fluctuation
2. wait the bus
voltage stable,
then repower on
20
0
E-200
Regenerative
resistor overload
Regenerative resistor
discharging power over
the rated
Change larger
power
regenerative
resistor
1
E-201
Regenerative
resistor
discharge too
long time
Regenerative resistor
connection error or
value too large
Change small
value resistor
and check the
wiring
22
0
E-220
Absolute
Encoder not connect or
Cut off drive