72
P3: speed control
P3-
XX
Name
Unit
Default
value
Range
Effec
tive
Suitable
mode
00
V-REF Function
Allocation
0:V-REF is input as speed
instruction.
1:V-REF will be used as
the input reference value
of the external speed limit.
The actual speed limit
depends on the external
analog speed limit.
2: Speed Feedforward
0
0~2
124
6
03
Speed instruction input
dead zone voltage
0.001v
0
0~500
4
05
Preset speed 1
rpm
0
-9999~+99
99
3
06
Preset speed 2
rpm
0
-9999~+99
99
3
07
Preset speed 3
rpm
0
-9999~+99
99
3
09
Acceleration time
ms
0
0~65535
34
10
Deceleration time
ms
0
0~65535
34
11
Reserved
12
Zero speed clamp mode
0: ZCLAMP input signal
is ON, forced speed
0
0~2
347