77
P5: signal setting
P5-
Name
Unit
Def
ault
Range
Effec
tive
Suita
ble
mode
00
Positioning finished width /COIN
Comman
d unit
7
0~65535
6
01
Positioning finished checking mode
0: offset absolute value below P5-00,
output COIN signal
1: offset below P5-00 after command
finished, output COIN signal
2: command finished, motor speed
below P5-03 and offset absolute
value below P5-00, output COIN
signal
3: command finished, offset absolute
value below P5-00, output COIN
signal. If COIN keeps the time
P5-02, output COIN-HOLD signal.
-
0
0~3
6
02
Positioning finished hold time
ms
0
0~65535
6
03
Rotation checking speed
rpm
50
0~10000
All
04
Same speed checking speed
rpm
50
0~10000
34
7
05
Reach checking speed
rpm
100
0
0~10000
34
7
06
Positioning near output width
Comman
d
unit
50
0~65535
6
07
Servo OFF delay time
ms
0
0~65535
All