en Translation of the Original Instructions
e-SV series Additional Installation, Operation and Maintenance Instructions 25
Model
DN, mm (in)
Forces, N (lbf)
Torques, Nm (lbf·in)
Fx
Fy
Fz
Mx
My
Mz
1, 3SV
25 (0,98)
200 (45)
180 (41)
230 (52)
240 (2124)
160 (1416)
190 (1682)
5SV
32 (1,26)
260 (59)
240 (54)
300 (68)
310 (2744)
210 (1859)
250 (2213)
10SV
40 (1,57)
330 (74)
300 (68)
370 (83)
390 (3452)
270 (2390)
310 (2744)
15, 22SV
50 (1,97)
450 (101)
400 (90)
490 (110)
420 (3718)
300 (2656)
340 (3010)
33SV
65 (2,56)
1800 (405)
1700 (382)
2000 (450)
1500 (13 276)
1050 (9294)
1200 (10 621)
46SV
80 (3,15)
2250 (506)
2050 (461)
2500 (562)
1600 (14 161)
1150 (10 179)
1300 (11 506)
66, 92SV
100 (3,94)
3000 (675)
2700 (607)
3350 (753)
1750 (15 489)
1250 (11 064)
1450 (12 834)
125SV
125 (4,92)
3700 (832)
3300 (742)
4100 (922)
2100 (18 587)
1500 (13 276)
1750 (15 489)
4.5 Electrical connection
DANGER:
All the hydraulic and electrical connections must be completed by a technician possessing the
technical
-professional requirements outlined in the current regulations.
DANGER: Electrical hazard
Before starting work, check that the unit is
unplugged and that the pump unit, the control
panel and the auxiliary control circuit cannot restart, even unintentionally.
NOTICE:
Before starting work, make sure that the general electric requirements and/or those of the
firefighting systems (hydrants or sprinklers) comply with local regulations.
4.5.1 Ground
DANGER: Electrical hazard
Always connect the external protection conductor (ground) to the ground terminal before
attempting to make any other electrical connections.
DANGER: Electrical hazard
Connect all the electrical accessories of the pump unit and motor to the ground.
DANGER: Electrical hazard
Check that the external protection conductor (ground) is longer than the phase conductors; In
case of accidental disconnection of the unit from
the phase conductors, the protection
conductor must be the last one to detach itself from the terminal.
DANGER: Electrical hazard
Install suitable systems for protection against indirect contact, in order to prevent lethal electric
shocks.

Table of Contents

Other manuals for Xylem LOWARA e-SV Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem LOWARA e-SV Series and is the answer not in the manual?

Xylem LOWARA e-SV Series Specifications

General IconGeneral
BrandXylem
ModelLOWARA e-SV Series
CategoryWater Pump
LanguageEnglish

Related product manuals