EasyManuals Logo

Xylem LOWARA e-SV Series User Manual

Xylem LOWARA e-SV Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
en Translation of the Original Instructions
e-SV series Additional Installation, Operation and Maintenance Instructions 33
Settling of the mechanical seal
The pumped liquid lubricates the seal faces of the mechanical seal; under normal conditions, a
small amount of liquid may leak out. When the unit is run for the first time, or immediately after
the seal is replaced, more liquid may temporarily leak out. To help the seal settle and to
reduce leaking:
1. Close and open the on-off valve on the discharge side two or three times with the unit
running.
2. Stop and start the unit two or three times.
5.5 Stopping
1. Shut the on-off valve located on the discharge line.
2. Stop the pump unit and check that the motor slows down gradually.
3. Gradually re-open the on/off valve and check that the motor remains still.

Table of Contents

Other manuals for Xylem LOWARA e-SV Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem LOWARA e-SV Series and is the answer not in the manual?

Xylem LOWARA e-SV Series Specifications

General IconGeneral
BrandXylem
ModelLOWARA e-SV Series
CategoryWater Pump
LanguageEnglish

Related product manuals