6.4 Tightening torques of the threaded connections
Table 1: Tightening torques of the threaded fittings, Nm (lbf in)
Model
A
B
C
D
E, F
G
H
I
J
1, 3, 5SV
M8
M12
-
-
G 3/8”
-
-
-
-
20 (177)
25 (220)
-
-
25 (220)
-
-
-
-
10, 15, 22SV
M10
M14
-
M8
G 3/8
-
-
-
-
35 (310)
30 (265)
-
20 (177)
25 (220)
-
-
-
-
33, 46, 66, 92SV
M12
M16
M6
M10
G 1/2”
R 3/8”
M16
-
-
60 (530)
60 (530)
8 (71)
35 (310)
40 (354)
40 (354)
40 (354)
-
-
125SV
M12
M16
M6
M10
G 1/2”
R 3/8”
M16
M10
M10
65 (575)
60 (530)
8 (71)
35 (310)
30 (265)
40 (354)
40 (354)
35 (310)
15 (133)
6.5 Spare parts ordering
Identify the spare parts with the product codes directly on the site www.lowara.com/spark.