e-HME type definition code
1.
Rated flow rate
[10] = m
3
/h
2.
Series name
[HM]
3.
Motor operation
[E] = e-SM
4.
Number of impeller
[03] = 3 impellers
5.
Material pump
[S] = Stainless steel (AISI 304)
6.
Motor rated power
kW x 10
7.
Phase
[M] = Single-phase
[T] = Three-phase
8.
Power Supply Voltage
e-SM Power supply
02 = 1x208-240 V
04 = 3x380-460 V
05 = 3x208-240/380-460 V
9.
Rotating part
[Q] = Silicon Carbide (Q
1
)
[V] = Aluminium oxide (Ceramic)
10.
Stationary part
[Q] = Silicon Carbide (Q
1
)
[B] = Carbon resin impregnated
11.
Elastomers
[E] = EPDM
[V] = FPM
[K] = FFPM (Kairez®)
12.
General characteristics
Null = None
Z = other
13.
General characteristics
Null = None
14.
Connections
Null = Threaded
15.
Null or letter assigned by the manufacturer
VME type definition code
1.
Rated flow rate
[10] = m
3
/h
2.
Series name
[VM]
3.
Motor operation
[E] = e-SM
4.
Number of impeller
[02] = 2 impellers
5.
Material pump
[P] = Stainless steel AISI 304 with Noryl™ impellers
6.
Motor rated power
kW x 10
7.
Phase
[M] = Single-phase pump unit
[T] = Three-phase pump unit
8.
Power Supply Voltage
[2] = 1x208-240 V
[4] = 3x380-460 V
[5] = 3x208-240/380-460 V
9.
Rotating part
[V] = Aluminium oxide (Ceramic)
10.
Stationary parts
Carbon resin impregnated
11.
Elastomers
[E] = EPDM