EasyManua.ls Logo

Xylem LOWARA e-SVE - Technical Information; Technical Specifications

Xylem LOWARA e-SVE
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
en Original instructions
48
9 Technical Information
e-SM Drive model
103
105
107
111
115
303
305
307
311
315
322
Input
Input frequency [Hz]
50/60 ± 2
Main supply
LN
L1 L2 L3
Nominal input voltage [V] 208÷240 ±10% 208÷240 / 380÷460 ±10%
380÷460
±10%
Maximum current
absorbed (AC) in
continuous service (S1)
[A]
See data plate
PDS Efficiency Class
IES2
Output
Min.÷Max. Speed [rpm]
800 to 3600
Leakage Current [mA]
< 3,5
I/O auxiliar + 15VDC
power supply [mA]
Imax < 40
Fault signal relay
1 x NO Vmax < 250 [VAC] , Imax < 2 [A]
1 x NO Vmax < 250 [VAC] , Imax < 2 [A]
Motor status relay
-
1 x NO Vmax < 250 [VAC] , Imax < 2 [A]
EMC (Electro Magnetic
Compatibility)
See Par. Declarations.
Installations must be performed in accordance with the EMC good practice guidelines
(e.g. avoid "eyebolts" on the transmission side)
Sound pressure LpA
[dB(A)] @ [rpm]
< 62 @3000
< 66 @3600
Insulation class
155 F
Protection class
IP 55, Enclosure Type 1
Protect the product from direct sunlight and rainfall
Relative humidity
(storage & operating)
5%÷95% UR
Storage temperature [°C]
/[°F]
-25÷65 / -13÷149
Operating temperature
[°C] /[°F]
-20÷50 / -4÷122
Air Pollution
Pollution Degree 2
Installation altitude a.s.l.
[m] / [ft]
< 1000 / 3280
Derating may occur at higher altitudes