RX-V1700/DSP-AX1700
23
RX-V1700/
DSP-AX1700
原因:パワーアンプに過電流が流れた。
補足:パワートランジスタの電流を検出していますので、
電流検出トランジスタをチェックすれば異常チャン
ネルが特定できます。
異常状態のままパワーオンすると、瞬時にプロテクション
がかかり、すぐに電源が切れます。
When there is a history of protection function: プロテクション履歴がある場合:
• Display provided when DIAG started
●ダイアグ起動時の表示
Cause: An excessive current flowed through the power
amplifier.
Suppleementary information: As current of the power
transistor is detected, the abnormal channel can be
identified by checking the current detect transistor.
Turning on the power without correcting the abnormality
will cause the protection function to work immediately and
the power supply will instantly be shut off.
Note)
• Applying the power to a unit without correcting the
abnormality can be dangerous and cause additional
circuit damage.
• The output transistors in each amplifier channel
should be checked for damage before applying any
power.
• Amplifier current should be monitored by measuring
across the emitter resistors for each channel.
本機のFLディスプレイにプロテクション履歴情報とバー
ジョン(英1文字)が表示され、数秒後にダイアグメニュー
(No.1DA70Y-YSS930のサブメニューMARGIN)になりま
す。
プロテクション履歴がない場合:
The FL display of the main unit displays the protection
function history data and the version (1 alphabet) then the
DIAG menu (sub-menu MARGIN of DIAG menu No.1
DA70Y-YSS930) a few seconds later.
When there is no history of protection function:
注意!
・ 異常を修正しないで、ユニットの電源をいれると、
危険な状態になり、さらに回路が損傷を受けること
になる場合があります。
・ 電源をいれる前に、各アンプのチャンネル内の出力
トランジスターに損傷がないかチェックしてくださ
い。
・ アンプの電流は、各チャンネルのエミッターの抵抗
器間で測定することによりモニターしてください。
Opening message/
オープニング表示
DIAG menu display/
ダイアグメニュー表示
After a few seconds
数秒後
Version (1 alphabet)
バージョン(英1文字)
When there is no history
of protection function
プロテクション履歴が
ない場合
NO PROTECT Z
1.DA70Y-YSS930
MARGIN
When there is a history ofprotection
function due to excess current
過電流によるプロテクション
履歴がある場合
Version (1 alphabet)
バージョン(英1文字)
I PROTECT Z