5-5
1
2
3
4
5
6
7
8
9
10
ELECTRICAL
ELECTRICAL COMPONENTS
CHECKING THE SWITCH CONTINUITY
Check each switch for continuity with the tester. If the con-
tinuity reading is incorrect, check the wiring connections
and if necessary, replace the switch.
Before checking for continuity, set the digital circuit tester
to the “” range.
When checking for continuity, switch back and forth
between the switch positions a few times.
CHECKING THE OIL PRESSURE SWITCH
1.
Drain:
Engine oil
2.
Disconnect:
Oil pressure switch lead
3.
Connect:
Digital circuit tester
(between the engine ground and oil pressure switch
terminal)
4.
Check:
Oil pressure switch continuity
No continuity Replace the oil pressure switch.
CHECKING THE TCI UNIT RESISTANCE
The following procedure applies to all of the TCI units.
1.
Check:
Coil resistance
Out of specification Replace.
Ω”
O.L”
Never insert the tester probes into the coupler termi-
nal slots. Always insert the probes from the opposite
end of the coupler, taking care not to loosen or dam-
age the leads.
Model 88 Multimeter with tachometer:
YU-A1927
NOTICE
Model 88 Multimeter with tachometer:
YU-A1927