3.4 Switch Settings
37
3.4 Switch Settings
■ SW1 Function Selection Switch (dip switches)
■ SW2 Linear Scale Pitch Setting (rotary switch)
* The default setting is 0 (0μm).
Switch No. Function At OFF At ON Default Setting
1
Status After DB Stop
During Base Block
Release DB after
motor stop
Continue DB after
motor stop
ON
2 Torque Reference Filter No Yes ON
3 Input Power Selection
DC-Power Input
Compatible
AC-Power Input
Compatible
ON
4
Linear Scale Polarity
Reversal
B-phase progression:
U, V, W direction
A-phase progression:
U, V, W direction
ON
(enabled only when
linear motor is used)
5
Regen Overload Alarm or
Warning
No Yes ON
6
Feedback Pulse
B-phase Reversal
Reversed Not reversed ON
7
Command Direction
Reversal
Reversed Not reversed ON
8 Not used ON
Setting Linear Scale Pitch Setting Setting Linear Scale Pitch Setting
0*
0μm
8 Not used
1
2μm
9 Not used
2
4μm
A Not used
3
20μm
B Not used
4
40μm
C Not used
5
800μm
D Not used
6
1000μm
E Not used