1.3 Devices and Components That Are Required to Build a System
1-6
1.3
Devices and Components That Are Required to Build a System
The following table lists the devices and components that are required to build the system that
is shown in 1.2 System Configuration Example on page 1-5. The numbers 1 to 12 correspond
to the numbers in the figure in 1.2 System Configuration Example on page 1-5.
No. Name Use Model Remarks
MP3300
CPU Module
Stores the module defini-
tions and programs, and
interprets the programs. The
CPU Module also controls
the Optional Modules.
Refer to the following section for details.
1.3.1 MP3300 Module/Unit List
on page 1-7
Base Unit
Provides the backplane to
which Modules are mounted
and supplies the required
power to the Modules.
Ethernet communica-
tions cables
Used to connect the CPU
Module to Ethernet commu-
nications devices or to con-
nect the CPU Module to a
PC that has the MPE720
installed on it.
Use a commercially available cable that meets
the following conditions:
• Ethernet specification: 100Base-TX
• Category 5 or higher
• Twisted-pair cable with RJ-45 connectors
Battery with Special
Connector
Provides power for the cal-
endar and backup memory
while the power is turned
OFF.
JZSP-BA01
The Battery is provided with
the CPU Module.
Power supply cable
Connects the power supply
of the Base Unit to a 24-
VDC power supply or an AC
power supply.
Use a commercially available cable that meets
the following conditions:
• Wire size: AWG18 to AWG13 (0.8 to 2.6
mm
2
)
• Twisted-pair cable
RLYOUT connector
cable
Connects the power supply
of the Base Unit to a 24-
VDC power supply, an AC
power supply, or a status
monitoring device.
Use a commercially available cable that meets
the following conditions:
• Wire size: AWG28 to AWG14 (0.08 to 2.0
mm
2
)
Front cover for unused
slot
Used to cover unused slots
on the Base Unit.
JEPMC-
OP3301-E
−
Optional Modules
Motion Modules, I/O Mod-
ules, and Communications
Modules are selected based
on the application.
Refer to the following section for details.
1.3.2 Optional Modules on page 1-8
MECHATROLINK-III
Cable
Connects the CPU Module
to MECHATROLINK-III com-
munications devices.
JEPMC-
W6012-
-E
Standard cable
Length: 0.2 to 50 m
JEPMC-
W6013-
-E
Cable with ferrite cores
Length: 10 to 50 m
JEPMC-
W6014-
-E
Cable with loose wires at one
end
Length: 0.5 to 50 m
SERVOPACK with
MECHATROLINK-III
Communications
Used to control Servomo-
tors.
SGD7S-
20
Σ
7S (Single-axis)
AC SERVOPACK with
MECHATROLINK-III Commu-
nications
SGD7W-
20
Σ
7W (Two-axis)
AC SERVOPACK with
MECHATROLINK-III Commu-
nications
Continued on next page.