3. SERVOPACK Installation
3.1. EMC Installation Conditions
This section gives the installation conditions that were used for EMC certification testing.
The EMC installation conditions that are given here are the conditions that were used to pass testing criteria at
Yaskawa. The EMC level may change under other conditions, such as the actual installation structure and wiring
conditions. These Yaskawa products are designed to be built into equipment. Therefore, you must implement EMC
measures and confirm compliance for the final equipment.
The applicable standards are EN 55011 group 1 class A, EN 61000-6-2, EN 61000-6-4, and EN 61800-3
(category C2, second environment).
3.1.1. SGDV-OSA01A
Three-Phase, 400 VAC
SGD7S-□□□D0 + SGDV-OSA01A
Symbol
Cable Name
Specification
I/O Signal Cable
Shielded cable
Servomotor Main Circuit Cable
Shielded cable
Encoder Cable
Shielded cable
Main Circuit Power Cable
Shielded cable
Communications Cable
Shielded cable
Safety signal cable
Shielded cable