Administrator’s Guide for SIP-T2 Series/T4 Series/T5 Series/CP920 IP Phones
524
Menu > Settings > Basic Settings > Sound > Ring Type for BLF Parked Call Monitor
Parameter
features.call_park.group_park_code <y0000000000xx>.cfg
Description
It configures the group call park code.
Note: It works only if “features.call_park.park_mode is set to 1 (FAC).
Permitted
Values
String within 32 characters
Default
Blank
Web UI
Features > Pickup & Park > Group Call Park Code
Parameter
account.X.callpark_enable
[1]
<MAC>.cfg
Description
It enables or disables Broadsoft call park feature.
Permitted
Values
0-Disabled
1-Enabled, the phone sends the subscription package to the server with the header "Event:x-broad-
works-callpark"
Default
1
[1]
X is the account ID. For T57W/T54W/T48U/T48S/T48G/T46U/T46S/T46G/T29G, X=1-16; for
T53W/T53/T43U/T42G/T42U/T42S, X=1-12; for T41P/T41S/T27G, X=1-6; for T40P/T40G/T23P/T23G, X=1-3; for T21
(P) E2, X=1-2; for T19(P) E2/CP920, X=1.
Broadsoft Emergency Call
Parameter
bw.emergency_calling.enable <y0000000000xx>.cfg
Description
It enables or disables the BroadWorks Emergency Calling feature.
Permitted
Values
0-Disabled
1-Enabled, the phone supports network hold and operator ring-back for emergency calls.
Default
0
BroadSoft Call Waiting Sync
Parameter
call_waiting.mode <y0000000000xx>.cfg
Description
It configures the call waiting mode.
Note: If it is set to 1 (XSI), it works only if “bw.xsi.enable" is set to 1 (Enabled).
Permitted
Values
0-Local
1-XSI, the status of the call waiting feature between the IP phone and the BroadWorks server can be
synchronized.
Default
0
Start2Start ACD Parameters
For more information on ACD, refer to Using_Star2Star_ACD_on_Yealink_IP_Phones.
Parameter
account.X.acd.call_information
[1]
<MAC>.cfg
Description
It configures the string the phone dials out when the ACD agent logs into/logs out of the ACD system
(you press the In/Out (LogIn/Out) soft key on the phone).
The value format: Call Center Number<time interval > User ID<time interval > Password.

Table of Contents

Other manuals for Yealink SIP-T46S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink SIP-T46S and is the answer not in the manual?

Yealink SIP-T46S Specifications

General IconGeneral
ManualYes
Cables includedLAN (RJ-45)
Number of handles included1 pc(s)
MountingDesk/Wall
Handset typeWired handset
Product typeIP Phone
Product colorBlack
Voice codecsCNG, G.711Mu, G.711a, G.722, G.723.1, G.726, G.729ab, VAD, iLBC
Lines quantity16 lines
Phonebook capacity1000 entries
Number of VoIP accounts16
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)10 - 95 %
Display diagonal4.3 \
Display resolution480 x 272 pixels
AC adapter input voltage100 - 240 V
AC adapter output current2 A
AC adapter output voltage5 V
Dual-Tone Multi-Frequency (DTMF) modesIn-band, Out-of band, SIP info
Volume controlDigital
Number of programmable keys10
USB 2.0 ports quantity1
Ethernet LAN (RJ-45) ports2
Networking standardsIEEE 802.3af
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet LAN interface typeGigabit Ethernet
Supported network protocolsSIP v1, SIP v2, LLDP/CDP/DHCP, OpenVPN, IEEE802.1X, IPv6, FTP/TFTP/HTTP/HTTPS
Harmonized System (HS) code85171800
Weight and Dimensions IconWeight and Dimensions
Depth213 mm
Width244 mm
Height185 mm
Package depth255 mm
Package width274 mm
Package height128 mm