| Configuring Account Settings | 94
Procedure
1. Do one of the following:
On your web user interface, go to Account > SIP Account.
On your VCS, go to More > Settings > Advanced > Account > SIP Account.
For VP59, tap > Settings > Advanced > Account > SIP Account.
On your CTP20/ CTP18, tap > Settings > Advanced > Account > SIP Account .
2. Configure and save the following settings:
Parameter Description Configuration Method
Line Active/SIP Account
Enable or disable SIP Accounts.
Note: the default value is On. If
it is set to disabled, the devices
cannot place or receive calls via
the SIP protocol.
Web user interface
Endpoint
CTP20/CTP18
Username
The username of this SIP
account.
Note: the default value is blank.
Web user interface
Endpoint
CTP20/CTP18
Register Name
The registration name of this SIP
account.
Note: the default value is blank.
Web user interface
Endpoint
CTP20/CTP18
Password
The registration password of this
SIP account.
Note: the default value is blank.
Web user interface
Endpoint
CTP20/CTP18
Server Host/Server
The IP address or domain name
of the SIP server.
Note: the default value is blank.
Web user interface
Endpoint
CTP20/CTP18
Port
Specify the port of the SIP
server.
Note: the default port number
is 5060. The value can be any
integer from 0 to 65535.
Web user interface
Endpoint
CTP20/CTP18
Enable Outbound Proxy
Server/Outbound
Enable or disable the device
to send requests of the SIP
account to the outbound proxy
server.
Default: Disabled.
Web user interface
Endpoint
CTP20/CTP18

Table of Contents

Other manuals for Yealink VCM38

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink VCM38 and is the answer not in the manual?

Yealink VCM38 Specifications

General IconGeneral
TypeConference microphone
Noise reductionYes
Microphone frequency100 - 16000 Hz
Microphone sensitivity-45 dB
Microphone pick-up range6 m
Number of microphone arrays8
Maximum sound pressure level (1kHz)100 dB
Device interfaceRJ-45
Connectivity technologyWired
Maximum operating distance40 m
Mounting typeCeiling
Product colorSilver
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 90 %
Number of products included1 pc(s)
Harmonized System (HS) code85181000
Power sourceDC/PoE
Sustainability certificatesCE, Federal Communications Commission (FCC), REACH, RoHS