13-13
IM 760401-01E
Communication Commands 1 (System of Commands before the IEEE 488.2-1987 Standard)
13
Query RR? <terminator>
Example RR0,0,0
Description Parameter error 12 will occur if an illegal
value is set.
If the recalling interval is set to 0 h 0 min 0 s,
the recalling interval is set to the display
update rate as when the data was stored.
While recalling or storing is in progress,
execution error 19 will occur.
RT/RT? Sets the rated integration time when
integrated values are to be output as an
analog signal/inquires about the current
setting.
Syntax RT m1,m2, m3 <terminator>
“m1” indicates the hours
0 m1 1000
“m2” indicates the minutes
0 m2 59
“m3” indicates the seconds
0 m3 59
Query RT? <terminator>
Example RT1,0
Description Parameter error 12 will occur if an illegal
value is set.
The maximum time that can be specified is
10000 (hours).
RV/RV? Sets voltage range/inquires about the
current setting.
Syntax RV m <terminator>
“m” indicates voltage range.
When the crest factor is set to 3
m= 3: 15V range
4: 30 V range
5: 60 V range
6: 100 V range
7: 150 V range
8: 300 V range
9: 600 V range
When the crest factor is set to 6
m= 3: 7.5 V range
4: 15 V range
5: 30 V range
7: 75 V range
8: 150 V range
9: 300 V range
Query RV? <terminator>
Example RV9
Description Parameter error 12 will occur if an illegal
value is set.
Changing of the voltage range is not allowed
while integration is in progress; execution
error 13 will occur.
While recalling or storing is in progress,
execution error 19 will occur.
SA/SA? Sets the external sensor scaling value/
inquires about the current setting.
Syntax When CM0 is set:
SA n <terminator>
When CM1 is set:
SA m,n <terminator>
“m” indicates element.
m= 0: All elements (Setting not
allowed during inquiry)
1: Element 1
2: Element 2 (for WT230 model
760503 only)
3: Element 3 (for WT230 only)
“n” indicates external sensor
scaling value.
0.001 n 9999
Query When CM0 is set:
SA? <terminator>
When CM1 is set:
SAm? <terminator>
Example When CM0 is set:
SA50.00
When CM1 is set:
SA1,50.00
Description Parameter error 12 will occur if “m” is set to
an illegal value.
Error 12 will occur when an inquiry is made if
the shunt current values set for each element
by CM0 differ from each other.
While recalling or storing is in progress,
execution error 19 will occur.
SC/SC? Determines whether or not to use the
scaling function/inquires about the
current setting.
Syntax SC m <terminator>
“m” indicates whether scaling is ON
or OFF.
m= 0: OFF
1: ON
Query SC? <terminator>
Example SC1
Description Parameter error 12 will occur if “m” is set to
an illegal value.
While recalling or storing is in progress,
execution error 19 will occur.
SI/SI? Sets the display update rate/inquires
about the current setting.
Syntax SI m <terminator>
"m" indicates the display update rate.
m= 0: 0.1 s
1: 0.25 s
2: 0.5 s
3: 1 s
4: 2 s
5: 5 s
Query SI? <terminator>
Example SI1
Description Parameter error 12 will occur if “m” is set to
an illegal value.
13.1 Commands

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA WT210 and is the answer not in the manual?

YOKOGAWA WT210 Specifications

General IconGeneral
BrandYOKOGAWA
ModelWT210
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals