Provides essential safety instructions for operating, installing, and servicing the equipment.
Explains the meaning of various safety alert symbols used in the document.
Details how the document content may change due to product improvements.
Explains how revisions are indicated within the document.
Defines the codes used in the system model number.
Defines the codes used in the compressor model number.
Defines the codes used in the vessel model number.
Defines the codes used in the VSD model number.
Provides an overview of the chiller's operation and components.
Explains the methods used to manage the chiller's output capacity.
Describes the operation and control of magnetic bearings.
Introduces the OptiView control center and its capabilities.
Details the layout and navigation of the OptiView control center display.
Covers language options and valid display ranges for analog inputs.
Lists common operator-level setpoints and their corresponding screens.
Describes the default display screen showing key operating parameters.
Provides a general overview of common chiller parameters for both shells.
Displays a cutaway view of the evaporator and its setpoints.
Displays a cutaway view of the condenser and its setpoints.
Details parameters and setpoints for the Head Pressure Control feature.
Displays controls for the liquid refrigerant level sensor and variable orifice.
Allows setting operational settings for refrigerant level control.
Shows compressor conditions and allows calibration of pre-rotation vanes.
Displays orientation of magnetic bearing axes and relevant parameters.
Provides additional parameters for the Magnetic Bearing Controller.
Displays the event history logs saved in the Magnetic Bearing Control Program.
Detects surge events and provides a running count over the chiller's lifetime.
Displays information pertinent to the VGD operation and manual control.
Maintains Variable Geometry Diffuser and pre-rotation vane setpoints.
Provides instructions to set VGD position feedback calibration.
Displays pre-rotation vane capability and calibration process.
Displays parameters associated with capacity control.
Displays information pertaining to the Variable Speed Drive (VSD).
Shows more detailed parameters associated with the Variable Speed Drive.
Displays information pertinent to the Motor Temperature Monitoring feature.
Provides a location for programming the most common setpoints.
Top level for general configuration parameters like time and date.
Contains programmable values for chiller operation schedule.
Allows definition of custom User IDs and matching passwords.
Allows definition of necessary communications parameters.
Allows definition of necessary communication parameters for the printer.
Allows definition of the sales order parameters.
Allows definition of general parameters related to chiller operation.
Allows the user to browse through system faults and shutdowns.
Shows system parameters at the time of a selected shutdown.
Displays a listing of the last 75 setpoint changes.
Shows details of a logged setpoint change.
Allows selection of up to 10 parameters for display.
Allows the technician to select parameters for the Custom View Screen.
Plots selected parameters in an X/Y graph format.
Used to configure the trending screen and data collection interval.
Sets up data collection start/stop triggers for trend analysis.
Displays slot numbers of commonly monitored parameters for trending.
Describes the messages displayed on the Status Line and Details Line.
Details messages related to chiller operation states and warnings.
Describes messages related to the Magnetic Bearing Controller startup sequence.
Lists messages indicating why the chiller is inhibited from starting.
Covers warnings related to MBC, Motor, Condenser, and Evaporator.
Details warnings for motor temperature and VSD input voltage imbalance.
Explains messages for local and remote stop commands.
Details messages related to cycling shutdowns and their causes.
Lists cycling shutdown messages related to MBC operations.
Details cycling shutdowns related to VSD operations.
Covers safety shutdowns for auxiliary contacts, condenser, and discharge.
Details safety shutdown messages related to MBC cable, data, and communication faults.
Covers MBC safety shutdowns for watchdog, EEPROM, temperature, and current.
Details VSD safety shutdowns for baseplate temperature and distortion.
Covers VSD safety shutdowns for input current, motor DCCT, and program faults.
Details VSD safety shutdowns related to voltage phase lock and rotation.
Introduces the OptiSpeed Compressor Drive (OSCD) design and features.
Highlights key features of the OSCD, such as direct liquid cooling.
Explains the advantages of the integrated harmonic filter.
Provides details on the integrated harmonic filter's function.
Describes the operation of OSCD with chiller for different amp models.
Explains how printers connect and the types of reports they can generate.
Details the wiring and connectors for different printer types.
Configures printer settings like baud rate, data bits, and parity.
Selects printer type and configures automatic data logging.
Instructions for establishing communication to download system histories.
Provides formulas to convert Fahrenheit to Celsius for temperature values.
Explains Magnetic Bearing Control positions given in micrometers.