Printer Configuration and Adjustment
Changing Printer Settings
7/3/13 P1056468-002
ESSID View the ESSID Value
The Extended Service Set Identification (ESSID) is an identifier for your wireless
network. This setting, which cannot be modified from the control panel, gives the
ESSID for the current wireless configuration.
Accepted values:
32-character alphanumeric string (default 125)
Related ZPL command(s):
none
SGD command used: wlan.essid
Control panel menu item: ESSID on page 34
Printer web page: none
Reset Network This option resets the wired or wireless print server. You must reset the print server to
allow any changes to the network settings to take effect.
Accepted values:
N/A
Related ZPL command(s):
~WR
SGD command used:
device.reset
Control panel menu item: RESET NETWORK on page 35
Printer web page:
Print Server Settings >
Factory Print Server Settings
Table 9 • Network Settings (Continued)

Table of Contents

Other manuals for Zebra 105SL Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra 105SL Plus and is the answer not in the manual?

Zebra 105SL Plus Specifications

General IconGeneral
Weight50 lbs / 22.7 kg
Humidity20-85% non-condensing
Print MethodThermal Transfer
Resolution203 dpi (8 dots/mm)
Max Print Width4.09 inches / 104 mm
Max Print Speed12 inches per second / 305 mm per second
Memory16 MB SDRAM, 8 MB Flash
Media Width0.79 inches / 20 mm to 4.5 inches / 114 mm
Media Thickness0.003 inches / 0.076 mm to 0.012 inches / 0.305 mm
Media TypesContinuous, die-cut, black mark
Ribbon Width2.00 inches / 51 mm to 4.33 inches / 110 mm
Ribbon Length1476'/450 m
ConnectivityParallel, Serial
Optional ConnectivityEthernet, Wireless
Power Requirements90-264 VAC; 48-62 Hz
Operating Temperature40°F to 105°F / 5°C to 40°C
Storage Temperature-40°F to 140°F / -40°C to 60°C