Accessories
83
Charging Temperature
Charge batteries in temperatures from 0 °C to 40 °C (32 °F to 104 °F). The battery charger always
performs battery charging in a safe and intelligent manner. At higher temperatures (for example,
approximately +37 °C (+98 °F)) the battery charger may for small periods of time alternately enable and
disable battery charging to keep the battery at acceptable temperatures. The battery charger indicates
when charging is disabled due to abnormal temperatures via its LED.
Table 15 Spare Battery LED Charging Indicators
LED Indication
Off The device, RS6000, or battery is not charging. The device, RS6000, or
battery is not inserted correctly in the cradle. Cradle is not powered.
Solid Amber Battery is charging.
Solid Green Battery charging is complete.
Fast Blinking Red
(2 blinks/second)
Charging error, for example:
• Temperature is too low or too high.
• Charging has gone on too long without completion (typically eight
hours).
Solid Red Unhealthy battery is charging or fully charged.