Possible faults 59
Fault
Cause of fault
How to rectify the fault
Person
responsible
Hydraulic oil
leaks from the
tank
Loose closing plug or
damaged seal
Tighten the plug or change the
seal
Qualified person
Loose ventilation filter
Tighten the filter
Qualified person
Oil level is too high
Check oil level with retracted
cylinders and drain some oil if
necessary
Qualified person
Hydraulic
installation
makes loud
noises
Oil level is too low
Check oil level with retracted
cylinders and top up oil if
necessary
Qualified person
Air or water in hydraulic oil
Bleed the system or replace oil if
necessary
Qualified person
Leaking suction hose in tank
Tighten screw connections and
replace suction hose if necessary
Qualified person
Hoses vibration
Tighten the fastening clamps and,
if necessary, use appropriate
washers (e.g. rubber)
Qualified person
The compaction
mechanism
moves very
slowly
Damaged hydraulic pump.
Have the pump replaced by a
service centre
Manufacturer
Leaks in the hydraulic system
Check the tightness of the
hydraulic components
Qualified person
Wrong oil type or old oil.
Check oil viscosity and purity and
replace if necessary
Qualified person
Installation too cold
Bring the installation to operating
temperature
Qualified person
Hydraulic oil is
too hot
Damaged hydraulic pump.
Have the pump replaced by a
service centre
Manufacturer
Wrong oil type or old oil.
Check oil viscosity and purity and
replace if necessary
Qualified person

Table of Contents