Chapter 28 Billing
UAG CLI Reference Guide
158
28.2.1 Billing Profile Sub-commands
The following table describes the sub-commands for the billing profile command.
[no] billing discount unit <2..10>
price price
Creates a new discount level by setting the duration of the billing period
that should be reached before the UAG charges users at this level and
defining this level’s charge per time unit.
The no command removes this discount level.
[no] billing profile profile_name Creates a billing profile and enters the billing profile sub-command
mode to set the price and the duration of the billing period. See Table 92 on
page 158 for the sub-commands.
The no command removes the specified profile.
profile_name: use up to 31 alphanumeric characters (A-Z, a-z, 0-9) and
underscores (_). Spaces are not allowed. The first character must be a
letter.
billing profile rename profile_name
profile_name
Renames the specified billing profile (first profile_name) to the specified
name (second profile_name).
billing tax-rate <0..100> Sets the tax rate. For example, type 6 for a 6% sales tax.
[no] billing tax-rate activate Sets the UAG to charge sales tax for the account.
The no command sets the UAG to not charge sales tax for the account.
billing unused-expire {day <1..30> |
hour <1..24> | minute <30..60>}
Specifies a time unit and number to set how long to wait before the UAG
deletes an account that has not been used.
[no] billing wlan-ssid-profile
profile_name
Sets the name of the SSID profile to which you can apply the general billing
settings.
The no command sets the UAG to not apply the billing settings to the SSID
profile.
show billing discount default rule Displays settings of the default discount price plan.
show billing discount rule Displays settings of the custom discount price plan(s).
show billing discount status Displays billing discount settings.
show billing profile [profile_name] Displays settings for all or the specified billing profile.
show billing status Displays the general billing settings, such as the accounting method or tax
rate.
Table 91 billing Commands (continued)
COMMAND DESCRIPTION
Table 92 billing profile Sub-commands
COMMAND DESCRIPTION
[no] activate Enables the billing profile.
The no command disables the profile.
price price Defines each profile’s price, up to 999999.99, per time unit.
time-period {day <1..365> | hour
<1..24> | minute <30..60>}
Sets the duration of the billing period. When this period expires, the user’s
access will be stopped.