3.4.2 Measurement Positions
The image below shows all positions at which the noise measurements have been performed. All measurements are performed
at a distance of 1 m away from the machine, at a height of 1.6 m.
3.4.3 Measurement Results
Below the results of the average A-weighted emission sound pressure level.
COMPONENT ACTION POSITION RESULT
Printer
Inert
Vacuum
A 73 dB (Appropriate PPE recommended)
B 78 dB (Appropriate PPE recommended)
Fill with
argon
A The measured value does not exceed 70 dB(A)
B 72.5 dB (Appropriate PPE recommended)
Job
A The measured value does not exceed 70 dB(A).
B The measured value does not exceed 70 dB(A).
For the actions resulting in measurements > 70 dB, it is recommended to wear hearing protection.