3.12 Customer Supplied Equipment
The equipment listed below is not a part of the DMP Factory 350 system. The customer can purchase this equipment from an
independent source or from 3D Systems (if so indicated).
3.12.1 Main Power Supply Cable
Supplied by: Customer
Installed by: 3D Systems
Required


EU: 5G (3 PH + 1 N + 1 GND) 6 mm²
US: 5G (3 PH + 1 N + 1 GND) 10 AWG
3.12.2 Vacuum Cleaner
Supplied by: Customer or 3D Systems
Installed by: Customer
Required
Installations must have a wet separator, explosion-proof vacuum cleaner . Use of the equipment and explosion risk assessment
should be in accordance to local regulations.


For more detailed information on the use of a wet separator vacuum cleaner to clean the machine, please
refer to the DMP Safety Guide (p/n: 80-D0712).
3.12.3 Floor Cleaning Machine
Supplied by: Customer
Installed by: Customer

3.12.4 Oxygen Monitor
Supplied by: Customer or 3D Systems
Installed by: Customer
Highly recommended
When working with argon, the customer is responsible for installing all appropriate facility safety devices as dictated by local
regulation. If required by local regulation a room area oxygen monitor (p/n: 23746-101-01 for 120VAC UL or p/n: 23746-101-
02 for 220VAC CE) can be purchased from 3D Systems. Customer is responsible to ensure these models are suitable for their
facility.
3.12.5 Dust Extraction System
Supplied by: Customer
Installed by: Customer
Highly recommended
3D Systems recommends a whole room, dust extraction system to remove airborne dust out of the air any time metal powder is
handled.

Table of Contents

Other manuals for 3D Systems DMP Flex 350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3D Systems DMP Flex 350 and is the answer not in the manual?

3D Systems DMP Flex 350 Specifications

General IconGeneral
Brand3D Systems
ModelDMP Flex 350
Category3D Printers
LanguageEnglish

Related product manuals