F. For other chillers
If using another chiller, make sure it falls within these guidelines:
Temperature inlet water: 20° +/- 1° C
Flow: Minimum 13 l/min - maximum 25 l/min
Max cooling power: 2.6 kW
Max pressure: 4 bar
1” BSP connection
Ensure an overpressure protection is install.
Adhere to cooling water and additives requirements provided by 3rd party supplier.