EasyManua.ls Logo

ABB 2 Series - Technical data; 10.1 Technical data tables

ABB 2 Series
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
69Technical data
EN
10. Technical data
This chapter contains information about the models, details of the equipment, characteristics and
technical data, overall dimensions and equipment identification.
A description of the equipment characteristics is provided to identify its main components and specify
the technical terminology used in the manual.
Chapter recipients:
Owner
Qualified installer
10.1 Technical data
10.1.1 Technical data table - Terra 60
EVSE Terra 60 CCT
Connector
Charging standard (IEC 61851-1) Mode 4 and Mode 3
Number of outputs 3
Number of EV served Base model up to three EV in parallel
Output combinations
2x CCS 2 connectors
AC Socket type 2
Cable type Air cooled cable
Cable Length Standard: 4.7 m
Efficiency > 95% at nominal output power
DC Output
DC output power Maximum 60kW
DC output voltage CCS: 150...920 Vdc
DC output current Nominal 150 A DC
Overvoltage category II
AC Output
AC output power 22kW
AC output voltage 400 VAC +/- 10% (50 Hz or 60 Hz)
AC output current Nominal 32A AC
AC output - Built-in RCD 30 mA type B

Table of Contents