Idx Parameter Description / Range / Selections / Notes
MESSAGE Message
Reserved to the User. DESCRIPTOR Descriptor
INSTALLATION_ DATE Installation date
DIAGNOSIS_CONDITION_IDX The writing of an Error code in this parameter updates the DIAGNOSIS_DETAILS with details of that error.
DIAGNOSIS_
DETAILS
COUNTER
all its details are returned by reading this parameter
N° of time the specified error has been detected during
the device’s life
TIME_COUNTER
Sum of all the periods of time the specified error has been
active as dd/hh/mm/ss
LAST_TIME
Time of when the error became active the last occurrence
as dd/hh/mm/ss
SPECIAL_RESTART
AR pre-setting
After the selection of one or more blocks from this list and
its writing to SPECIAL_RESTART, then the restart
operation is executed by writing “Special Restart” in the
RB_RESTART.
All the selected Blocks are set with a pre-defined
configuration allowing their switching to AUTO Mode.
PS: The Function Blocks must have been previously
instantiated into a Function Block Application otherwise
cannot move out from OOS.
IS pre-setting
IT pre-setting
SC pre-setting
PID pre-setting
CS pre-setting
AI pre-setting
RB pre-setting
SPECIAL_OPERATIONS
Do nothing
See the
dedicated
section
Reset Device Configuration to Default Configuration
Reset PdP Sensor Trimming to Factory Trim
Reset PdP Sensor Trimming to User Trim
Reset Static Press Sensor Trimming to Factory Trim
Reset Static Press Sensor Trimming to User Trim
Reset Sensor Temp Trimming to Factory Trim
Reset Sensor Temp Trimming to User Trim
Save current Device Configuration as Default Configuration
Save actual PdP Sensor Trimming as PdP Factory Trim
Save actual Static Press Sensor Trimming as Static Press Factory Trim
Save actual Sensor temp Trimming as Sensor Temp Factory Trim
Save actual PdP Sensor Trimming as PdP User Trim
Save actual Static Press Sensor Trimming as Static Press User Trim
Save actual Sensor temp Trimming as Sensor Temp User Trim
LOCAL_OPERATIONS
Local operation via PUSH BUTTONS are not allowed
1: Enabled
Default
Local operation via PUSH BUTTONS are allowed
DEVICE_SERIAL_NUMBER Serial Number of the Transmitter as printed on the main Type Plate (on the housing).