Cat Error HMI code Description Possible Cause Suggested Actions
Pressure sensor errors
Sensor Temperature Fail 
The measurement accuracy is
decreased more than the acceptable
error
The circuitry for the sampling of the
temperature has failed.
The Sensor must be replaced
Non-Volatile memory
burn error

The device continue to work without
problems but any replacement
operation is compromised because
the back-up configuration is not
updated
Writings to the Sensor non-Volatile
Memory was not successful
The Sensor should be replaced as
soon as possible.
Installation / start-up errors
RB Out of Service
Device configured to be Out of
Service or initializing
Resource Block is configured to be
Out of Service
The TARGET MODE of the Resource
Block must be switched in AUTO
Input
Simulation
Active
PdP
simulation

The Process Value is simulated to
became the P-dP value measured in
input
The P-dP Value in output is
calculated from a value simulated in
input
Use DD based configurator
(AVB Professional - Hand held) to
place device back into normal
operating mode
(Remove the input simulation)
Static
Pressure
simulation
The Process Value is simulated to
became the Static Pressure value
measured in input
The Static Pressure Value in output
is calculated from a value simulated
in input
Sensor
Temp
simulation
The Sensor Temperature Value is
simulated to became the measured
Sensor Temperature value
The Sensor Temperature Value in
output is calculated from a value
simulated in input
Replace
Info
Replace
required –
Both data
direction
valid

The Replace operation is required
after the changing of the electronics
or of the sensor
The Electronics or the Sensor have
been changed but the replacement
operation has not been executed
The replacement operation must be
executed:



has been changed between new
Sensor or new electronics
– Power Cycle the device


Replace
required –
FE to CB
not
applicable
The Replace operation is required
after the changing of the electronics
or of the sensor
The Electronics or the Sensor has
been changed and a replacement
operation for a new sensor has to be
executed.
The replacement operation must be
executed:
Only electronics data can be copied
into the sensor



– Power Cycle the device


Replace
enabled –
FE to CB
not
applicable
The Replace operation has been
attempted but with wrong direction
The Electronics or the Sensor have
been changed, The replacement has
been enabled but with a wrong

Change the replacement direction
(if possible)

replace mode

– Power Cycle the device


Process errors
Pressure Overrange  An overpressure has been detected
This effect could be produced by
other equipment on the process,
(valves…). Exceeding the pressure
range can cause reduced accuracy or
mechanical damage to the
diaphragm material and may require
calibration/replacement.
The compatibility of pressure
transmitter model and process
conditions has to be checked. A
different transmitter type could be
required