Technical data 121
Losses, cooling data and noise
Terminal and lead-through data for the power cables
IEC
Door opening:
Drive type Frame Air flow Heat dissipation Noise
m
3
/h ft
3
/min
W dB(A)
U
N
= 400 V
ACS580-07-0495A-4 R10 2950 1837 6102 72
ACS580-07-0575A-4 R10 2950 1837 6909 72
ACS580-07-0640A-4 R10 2950 1837 8622 72
ACS580-07-0715A-4 R11 2950 1837 9264 72
ACS580-07-0810A-4 R11 2950 1837 10362 72
ACS580-07-0870A-4 R11 3170 1978 11078 71
Frame
size
Number of holes
in the lead-
through plate for
the power cables.
Hole diameter
60 mm.
Terminals L1, L2, L3, U2, V2, W2 Grounding terminals
Max. phase
conductor
size
Bolt size Tightening
torque
Bolt size Tightening
torque
mm
2
N·m
R10 12 3×240 or
4×185
M12 50...75 N·m M10 30...44 N·m
R11 12 4×240 or
5×185
M12 50...75 N·m M10 30...44 N·m
800 mm (31.50 in.)