EasyManua.ls Logo

ABB ACS580-07-0495A-4 - Page 171

ABB ACS580-07-0495A-4
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Optional I/O extension modules 167
Ambient conditions: See the drive technical data.
Package: Cardboard
Isolation areas:
Motor thermistor connection (60…61):
Wire size max. 1.5 mm
2
Supported standards: DIN 44081 and DIN 44082
Number of PTC thermistor relays: 1 or 3…6 in series
Triggering threshold: 3.6 kohm
Recovery threshold: 1.6 kohm
PTC terminal voltage: < 5.0 V
PTC terminal current: < 1 mA
Short-circuit detection: < 50 ohm
Relay output (62…63):
Wire size max. 1.5 mm
2
Maximum contact rating: 250 V AC / 30 V DC / 5 A
Maximum breaking capacity: 1000 VA
External power supply (40…41):
Wire size max. 1.5 mm
2
24 V AC / V DC ±10% (GND, user potential)
Maximum current consumption: 25 W, 1.04 A at 24 V DC
Symbol Description
Reinforced insulation (IEC 61800-5-1:2007)
CMOD-02
PTC
in
RO
PTC
24 V
in
Plugged
to drive
SLOT2

Table of Contents

Related product manuals