Page #21 background imageLoading...
Page #21 background image
19
Hardware
3ADW000197R0101 DCS800-R Sel e a
Pulse transformer board SDCS-PIN-48
This board is always required with the rebuild kit.
Normally one SDCS-PIN-48 board per 6 thyristors, if the board can be placed
close (gate wires <1 m) to all 6 thyristors of one bridge.
G
C
G
C
G
C
G
C
G
C
Gate
Cathode
X113
X1
X213
X2
SDCS-PIN-48
AB CDEF
270
100
G
C
Pin48.dsf
line potential !
conductive supports
8 301
317
8010
260
85 85 85
7.5
5
4.8
5
8010
Card holder for SDCS-PIN-48
10~ 60
SDCS-PIN-48 board and card holder
Wiring
The gate-cathode wires, which are a part of the rebuild kit's delivery, have to be
handled in this way:
- One end is equipped with a coded plug, which fits the C and G pins on the
SDCS-PIN-48
- The cable length in the delivery condition is 2 m. The cable routing should be
done, to end up with a cable length as short as possible; the max. cable length
is 1 m. The cables have to be shortened and have to be equipped with the plug
connector, demanded by the thyristor type in use.

Table of Contents

Other manuals for ABB DCS800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB DCS800 and is the answer not in the manual?

ABB DCS800 Specifications

General IconGeneral
Control TypeDigital
Supply Voltage380 ... 690 V AC
Input Voltage Range380 V to 690 V AC
Control ModeTorque, Speed
Cooling MethodAir-cooled
Communication ProtocolsModbus, Profibus, CANopen
Communication OptionsEthernet
Protection ClassIP21, IP54
Enclosure RatingIP00, IP21, IP54
ProtectionOvercurrent, Overvoltage, Overtemperature
Ambient Temperature0 to 40°C
Field SupplyIntegrated or External