EasyManuals Logo

ABB DCS800 Installation And Start-Up Manual

ABB DCS800
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
5
Introduction
3ADW000xxxR0101 DCS800-R Sel e a
Introduction
How to use this manual
The purpose of this manual is to provide you with the information
necessary to select the right rebuild kit with all the necessary or
available options, to install it, do the start-up and operate it as a DC
drive system. Depending on the kit's configuration, different func-
tionality and different options concerning the user interface are
available. As long as the hardware needs to be named or cross-
referenced to in a very general way, the term Rebuild kit will be
used.
Contents of this manual
Introduction describes how to use this manual and the boundary
conditions applying.
Basic Selection provides the information about the types of the
Rebuild kits, their type designations and options.
Hardware description provides the information about the boards
and components
Interfacing the Electronics and Thyristors provides the informa-
tion about the configurations and functions of drives and examples
of the whole circuit diagram.
Installation provides the information about required ambient condi-
tions, space requirements, cabling and wiring and how to install a
rebuild system.
Start-up gives some general guidelines and cross references how
to commission and start up a DC drive system using a Rebuild kit.
Associated publications
Associated publications see inner page of the jacket of that manual.

Table of Contents

Other manuals for ABB DCS800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB DCS800 and is the answer not in the manual?

ABB DCS800 Specifications

General IconGeneral
Control TypeDigital
Supply Voltage380 ... 690 V AC
Input Voltage Range380 V to 690 V AC
Control ModeTorque, Speed
Cooling MethodAir-cooled
Communication ProtocolsModbus, Profibus, CANopen
Communication OptionsEthernet
Protection ClassIP21, IP54
Enclosure RatingIP00, IP21, IP54
ProtectionOvercurrent, Overvoltage, Overtemperature
Ambient Temperature0 to 40°C
Field SupplyIntegrated or External